Mushroom Farming Machine

Mushroom farming machines supplied and commissioned by MushroomWale — Daikin and Carrier air-cooled climate units, centrifugal humidifiers and foggers, fresh-air blowers, motorised damper actuators, digital controllers and compost handling machinery. Every machine is sized against real room load, not catalogue tonnage, and is supported by the same engineers who commission MushroomWale turnkey farms.

Mushroom Farming Machine available online

30 items listed with live pricing or quote-on-request.

Machines used in commercial mushroom farming

Mushroom yield is a climate outcome. These are the machines that actually decide whether a room holds 16–18°C at 85–90% RH with controlled CO₂ through an Indian summer.

  • Climate units: Daikin (R32 / R410A HMT) and Carrier (Haier-CCR, R-404a commercial refrigeration) systems for 18×40, 18×60 and 18×70 ft rooms.
  • Humidification: centrifugal humidifiers and high-pressure foggers with water treatment.
  • Air handling: fresh-air blowers (1 HP upwards), GI ducting and motorised damper actuators for CO₂ control.
  • Compost side: turning, filling and aeration machinery for Phase 1 and Phase 2 units.

Mushroom farming machine price in India

Machine cost is driven by room volume, ambient design temperature and running hours. Indicative climate unit pricing on this site ranges from about ₹2.07 lakh to ₹4.64 lakh per room depending on model and brand. GST at 18% and transportation are extra, and any additional client requirement is treated as extra work.

Correct machine sizing matters more than brand

An undersized unit runs continuously and still misses set point; an oversized unit short-cycles and pushes humidity out of range. Share your room dimensions, insulation thickness, bag load and location, and our engineers will confirm the machine model and electrical load before you commit.

How to choose a mushroom farming machine

Machine selection is an engineering calculation, not a catalogue pick. These six checks decide whether your room holds 16–18°C at 85–90% RH through an Indian summer.

  1. 1

    1. Start from room volume, not floor area

    An 18×40 ft room and an 18×70 ft room differ in air volume and bag load, so they need different tonnage and different air-change rates.

  2. 2

    2. Use your local design temperature

    Peak ambient in your district drives condenser duty. A machine sized for a mild location will miss set point in a hot, dry summer.

  3. 3

    3. Count the real internal heat load

    Compost respiration, lighting, people and fresh-air intake all add load. Bag load per room is the biggest variable and must be declared before sizing.

  4. 4

    4. Pick the brand and refrigerant duty

    Daikin (R32 / R410A HMT) is the default. Carrier (Haier-CCR) uses R-404a commercial refrigeration and is offered for 18×40, 18×60 and 18×70 ft rooms where that duty suits the site.

  5. 5

    5. Size humidification and fresh air together

    Cooling without matched humidification dries the crop; fresh air without dampers loses CO₂ control. Quote the humidifier, blower, ducting and actuator as one set.

  6. 6

    6. Confirm connected load and DG backup

    Ask for the connected-load note including starting surge before ordering, so your electrical contractor and DG set are sized correctly the first time.

Machine comparison — specs, use case and suitable farm size

Indicative comparison of the machines used on commercial mushroom farms. Final model, tonnage and price are confirmed after a room-load check.

  • Daikin climate unit (R32 / R410A HMT)

    Key specification
    Air-cooled, high-ambient duty, cooling + dehumidification
    Best use case
    Default choice for grow rooms across most Indian districts
    Suitable farm size
    18×40, 18×60 and 18×70 ft rooms
    Indicative price
    Approx. ₹2.07 lakh – ₹4.64 lakh per room by size
  • Carrier climate unit (Haier-CCR, R-404a)

    Key specification
    Commercial refrigeration duty, R-404a
    Best use case
    Alternative where R-404a commercial duty suits the site
    Suitable farm size
    18×40, 18×60 and 18×70 ft rooms only
    Indicative price
    Approx. ₹2.07 lakh – ₹4.64 lakh per room by size
  • Centrifugal humidifier

    Key specification
    Motorised atomising head, room-mounted, treated water feed
    Best use case
    Holding 85–90% RH during pinning and cropping
    Suitable farm size
    One or more per room by room volume
    Indicative price
    Mid-range per unit — see product card
  • High-pressure fogger system

    Key specification
    Pump + nozzle line, fine droplet fogging
    Best use case
    Larger rooms or where uniform RH is hard to hold
    Suitable farm size
    18×60 ft rooms and above, multi-room farms
    Indicative price
    Quoted per room line
  • Fresh-air blower + damper actuator

    Key specification
    1 HP upwards blower, GI duct, motorised damper
    Best use case
    Fresh-air exchange and CO₂ control
    Suitable farm size
    One set per grow room
    Indicative price
    Per set, sized by room volume
  • Compost machinery (turner / filling)

    Key specification
    Phase 1 and Phase 2 handling and aeration equipment
    Best use case
    In-house compost production instead of bought-in compost
    Suitable farm size
    Farms producing their own compost, larger tonnage
    Indicative price
    Project-specific — quoted on tonnage

Prices are indicative ex-Firozabad. GST @ 18% and transportation are extra, and any additional client requirement is treated as extra work.