Button mushrooms cropping on bags stacked on racks in a MushroomWale grow room
Grow Rooms

Standard Button Mushroom Grow Rooms

All MushroomWale rooms follow correct engineering rules, airflow design, and continuous production math for Indian climates up to 50°C.

  • 50°CMax Ambient Temp
  • 60 DaysCycle Length
  • 2 kg/bagYield Standard
  • DaikinRefrigeration
Four standard rooms

Standard Grow Room Models & Specifications

18 × 30 ft

Standard Grow Room

1,000+Bags (10kg)
2,000 kgPer Cycle

Incubation: Day 0–30 | Production: Day 30–60

Cycle Avg33.3 kg/day(60 days)
Harvest Avg66.7 kg/day(30 days)
Dimensions
18×30 ft
Height (Front/Back)
16/14 ft
Rack Layout
2 rows × 22 ft
Rack Configuration
2 Rows × 7 Tiers
Daikin AC
6 TR
LED Battens
14 units

18 × 40 ft

Standard Grow Room

1,600+Bags (10kg)
3,200 kgPer Cycle

Incubation: Day 0–30 | Production: Day 30–60

Cycle Avg53.3 kg/day(60 days)
Harvest Avg106.7 kg/day(30 days)
Dimensions
18×40 ft
Height (Front/Back)
16/14 ft
Rack Layout
2 rows × 32 ft
Rack Configuration
2 Rows × 7 Tiers
Daikin AC
8 TR
LED Battens
20 units

18 × 60 ft

Standard Grow Room

2,500+Bags (10kg)
5,000 kgPer Cycle

Incubation: Day 0–30 | Production: Day 30–60

Cycle Avg83.3 kg/day(60 days)
Harvest Avg166.7 kg/day(30 days)
Dimensions
18×60 ft
Height (Front/Back)
16/14 ft
Rack Layout
2 rows × 52 ft
Rack Configuration
2 Rows × 7 Tiers
Daikin AC
10 TR
LED Battens
32 units
RECOMMENDED COMMERCIAL MODEL

18 × 70 ft

Standard Grow Room

3,000+Bags (10kg)
6,000 kgPer Cycle

Incubation: Day 0–30 | Production: Day 30–60

Cycle Avg100 kg/day(60 days)
Harvest Avg200 kg/day(30 days)
Dimensions
18×70 ft
Height (Front/Back)
16/14 ft
Rack Layout
2 rows × 62 ft
Rack Configuration
2 Rows × 7 Tiers
Daikin AC
12 TR
LED Battens
40 units
Effective 01 Sep 2026

Pricing & Models

Compare Daikin and Carrier (Haier-CCR) refrigeration systems for mushroom cold rooms (16–18 °C, 85–95% RH). Customer prices below are ex-GST and feed every quotation, calculator, and PDF in real time.

18×30 ft

540 sq ft · 6.0 TR design load

Daikin (Ex-GST)

₹2,00,640

Outdoor Unit (ODU)

  • 1×
    Outdoor Unit — 6 HP, R410A 3ph HMT Condensing Unit

Indoor Unit (IDU)

  • 1×
    Indoor Unit — 14 kW HMT Evaporator, 550mm fan

18×40 ft

720 sq ft · 8.0 TR design load

Daikin (Ex-GST)

₹3,05,710

Outdoor Unit (ODU)

  • 2×
    Outdoor Unit — 4 HP, R32 3ph HMT Condensing Unit

Indoor Unit (IDU)

  • 1×
    Indoor Unit — 24 kW HMT Dual-Circuit Evaporator, 550mm fan

18×60 ft

1080 sq ft · 10.0 TR design load

Daikin (Ex-GST)

₹3,19,295

Outdoor Unit (ODU)

  • 1×
    Outdoor Unit — 4 HP, R32 3ph HMT Condensing Unit
  • 1×
    Outdoor Unit — 6 HP, R410A 3ph HMT Condensing Unit

Indoor Unit (IDU)

  • 1×
    Indoor Unit — 24 kW HMT Dual-Circuit Evaporator, 550mm fan

18×70 ft

1260 sq ft · 12.0 TR design load

Daikin (Ex-GST)

₹3,38,960

Outdoor Unit (ODU)

  • 2×
    Outdoor Unit — 6 HP, R410A 3ph HMT Condensing Unit

Indoor Unit (IDU)

  • 1×
    Indoor Unit — 28 kW HMT Dual-Circuit Evaporator, 550mm fan

Refrigerant by brand

Daikin uses HMT-class R32 / R410A split units. Carrier (Haier-CCR) commercial refrigeration units run on R-404a. Both are tuned for mushroom rooms at 16–18 °C and 85–95% RH.

Auto-synced totals

Quotation PDFs, Investment Calculator, and Auto-Quotation pull these prices live — no manual recalculation needed.

Source: Daikin Price List w.e.f. 01.09.2026. Prices exclude GST @ 18%, refrigerant piping, cables, MS stand, civil & electrical feeds.

Daikin vs Carrier — which should I pick?

Both are authorised brands we install and support. Daikin offers detailed ODU + IDU pairing with HMT R32 / R410A. Carrier (Haier-CCR) provides competitive pricing with BTU-matched commercial refrigeration units running on R-404a, designed for +18°C cropping conditions.

Carrier is available for 18×40, 18×60, and 18×70 ft rooms only. For 18×30 ft, Daikin remains the sole option. Toggle the brand selector above to compare prices instantly.

Continuous production

Production Estimates: How Many Rooms Do I Need for Daily Harvest?

Understanding continuous production logic

Formula

Production rooms needed (M):
M = ceil(Target kg/day ÷ Harvest rate/room)
Total rooms needed (N):
N = 2 × M
(Half incubating, half producing)

Per-Room Harvest Rates

  • 18 × 30 ft66.7 kg/day
  • 18 × 40 ft106.7 kg/day
  • 18 × 60 ft166.7 kg/day
  • 18 × 70 ft200 kg/day

Example: 500 kg/day Target

Using 18×70 ft rooms (200 kg/day harvest rate):

M = ceil(500 ÷ 200) = 3 production rooms
N = 2 × 3 = 6 total rooms

At any time, 3 rooms are in incubation (Day 0–30) and 3 rooms are producing (Day 30–60). This ensures continuous daily harvest.

Calculator

MushroomWale Production Calculator

Plan your project with accurate calculations

How many rooms do I need?

Results

Rooms in Production3
Total Rooms Required6
Actual Daily Output600.0 kg/day
Annual Output2,19,000 kg
Inside every room

Climate, Production & Electrical Specifications

Climate & Airflow System

Included in all room models

  • Dampers & Gravity Louvers
  • Insulated Ducts
  • CO₂ Controller
  • Temperature & RH Control
  • PLC Control Panel
  • Misting/Water Sprayer Line
  • Water Tank Connection

Production Parameters

60-day crop | cropping 16–18 °C, RH 85–90%, CO₂ under 1,000 ppm

  1. Spawn Run
    Mycelium colonisation; compost held at 24–25°C
    22–24°C
  2. Case Run
    Casing applied, 7–10 day case run
    24–25°C
  3. Pinning
    Air down over 24–48 h; CO₂ under 1,000 ppm
    17–18°C
  4. Cropping
    Harvest period, RH 85–90%
    16–18°C

Electrical Specifications

Panel compatible with high ambient load (45–50°C)

Sensor Wiring
1 mm copper
Light Wiring
1.5 mm copper
Machine Wiring
4 mm 4-core
Comparison

Quick Comparison

Side-by-side specifications of all standard room models

Specification18 × 30 ft18 × 40 ft18 × 60 ft18 × 70 ftRecommended
Bag Capacity1,000+1,600+2,500+3,000+
Yield per Cycle2,000 kg3,200 kg5,000 kg6,000 kg
Cycle Average (60 days)33.3 kg/day53.3 kg/day83.3 kg/day100 kg/day
Harvest Average (30 days)66.7 kg/day106.7 kg/day166.7 kg/day200 kg/day
Rack Length22 ft32 ft52 ft62 ft
Daikin AC6 TR8 TR10 TR12 TR
BTU Rating72,000 BTU96,000 BTU120,000 BTU144,000 BTU
LED Battens14 units20 units32 units40 units
A finished MushroomWale PUF panel grow room with its door, controller and cooling units
Next step

Ready to Build Your Mushroom Project?

Use our calculators to plan your production capacity or get a detailed quotation for your grow room setup.

Mushroom Grow Room FAQs