MushroomWale - Turnkey Mushroom Project Solutions
    You're offline — cached content is available
    Grow Rooms

    Standard Button Mushroom Grow Rooms

    All MushroomWale rooms follow correct engineering rules, airflow design, and continuous production math for Indian climates up to 50°C.

    50°C
    Max Ambient Temp
    60 Days
    Cycle Length
    2 kg/bag
    Yield Standard
    Daikin
    Refrigeration

    Standard Grow Room Models & Specifications

    18 × 30 ft

    Standard Grow Room

    1,000+
    Bags (10kg)
    2,000 kg
    Per Cycle
    Incubation: Day 0–30 | Production: Day 30–60
    Cycle Avg
    33.3 kg/day
    (60 days)
    Harvest Avg
    66.7 kg/day
    (30 days)
    Dimensions18×30 ft
    Height (Front/Back)16/14 ft
    Rack Layout2 rows × 22 ft
    Rack Configuration2 Rows × 7 Tiers
    Daikin AC6 TR
    LED Battens14 units

    18 × 40 ft

    Standard Grow Room

    1,600+
    Bags (10kg)
    3,200 kg
    Per Cycle
    Incubation: Day 0–30 | Production: Day 30–60
    Cycle Avg
    53.3 kg/day
    (60 days)
    Harvest Avg
    106.7 kg/day
    (30 days)
    Dimensions18×40 ft
    Height (Front/Back)16/14 ft
    Rack Layout2 rows × 32 ft
    Rack Configuration2 Rows × 7 Tiers
    Daikin AC8 TR
    LED Battens20 units

    18 × 60 ft

    Standard Grow Room

    2,500+
    Bags (10kg)
    5,000 kg
    Per Cycle
    Incubation: Day 0–30 | Production: Day 30–60
    Cycle Avg
    83.3 kg/day
    (60 days)
    Harvest Avg
    166.7 kg/day
    (30 days)
    Dimensions18×60 ft
    Height (Front/Back)16/14 ft
    Rack Layout2 rows × 52 ft
    Rack Configuration2 Rows × 7 Tiers
    Daikin AC10 TR
    LED Battens32 units
    RECOMMENDED COMMERCIAL MODEL

    18 × 70 ft

    Standard Grow Room

    3,000+
    Bags (10kg)
    6,000 kg
    Per Cycle
    Incubation: Day 0–30 | Production: Day 30–60
    Cycle Avg
    100 kg/day
    (60 days)
    Harvest Avg
    200 kg/day
    (30 days)
    Dimensions18×70 ft
    Height (Front/Back)16/14 ft
    Rack Layout2 rows × 62 ft
    Rack Configuration2 Rows × 7 Tiers
    Daikin AC12 TR
    LED Battens40 units
    Effective 01 May 2026

    Pricing & Models

    Compare Daikin and Carrier (Haier-CCR) refrigeration systems for mushroom cold rooms (16–18 °C, 85–95% RH). Customer prices below are ex-GST and feed every quotation, calculator, and PDF in real time.

    18×30 ft

    540 sq ft · 6.0 TR design load

    Daikin (Ex-GST)

    2,04,930

    Outdoor Unit (ODU)

    • 1×
      Outdoor Unit 6 HP, R410A 3ph HMT Condensing Unit

    Indoor Unit (IDU)

    • 1×
      Indoor Unit 14 kW HMT Evaporator, 550mm fan

    18×40 ft

    720 sq ft · 8.0 TR design load

    Daikin (Ex-GST)

    3,12,246

    Outdoor Unit (ODU)

    • 2×
      Outdoor Unit 4 HP, R32 3ph HMT Condensing Unit

    Indoor Unit (IDU)

    • 1×
      Indoor Unit 24 kW HMT Dual-Circuit Evaporator, 550mm fan

    18×60 ft

    1080 sq ft · 10.0 TR design load

    Daikin (Ex-GST)

    3,26,106

    Outdoor Unit (ODU)

    • 1×
      Outdoor Unit 4 HP, R32 3ph HMT Condensing Unit
    • 1×
      Outdoor Unit 6 HP, R410A 3ph HMT Condensing Unit

    Indoor Unit (IDU)

    • 1×
      Indoor Unit 24 kW HMT Dual-Circuit Evaporator, 550mm fan

    18×70 ft

    1260 sq ft · 12.0 TR design load

    Daikin (Ex-GST)

    3,46,203

    Outdoor Unit (ODU)

    • 2×
      Outdoor Unit 6 HP, R410A 3ph HMT Condensing Unit

    Indoor Unit (IDU)

    • 1×
      Indoor Unit 28 kW HMT Dual-Circuit Evaporator, 550mm fan (new in 01.05.2026 list)

    Refrigerant by brand

    Daikin uses HMT-class R32 / R410A split units. Carrier (Haier-CCR) commercial refrigeration units run on R-404a. Both are tuned for mushroom rooms at 16–18 °C and 85–95% RH.

    Auto-synced totals

    Quotation PDFs, Investment Calculator, and Auto-Quotation pull these prices live — no manual recalculation needed.

    Source: Daikin Price List w.e.f. 01.05.2026. Prices exclude GST @ 18%, refrigerant piping, cables, MS stand, civil & electrical feeds.

    Daikin vs Carrier — which should I pick?

    Both are authorised brands we install and support. Daikin offers detailed ODU + IDU pairing with HMT R32 / R410A. Carrier (Haier-CCR) provides competitive pricing with BTU-matched commercial refrigeration units running on R-404a, designed for +18°C cropping conditions.

    Carrier is available for 18×40, 18×60, and 18×70 ft rooms only. For 18×30 ft, Daikin remains the sole option. Toggle the brand selector above to compare prices instantly.

    Production Estimates: How Many Rooms Do I Need for Daily Harvest?

    Understanding continuous production logic

    Formula

    Production rooms needed (M):
    M = ceil(Target kg/day ÷ Harvest rate/room)
    Total rooms needed (N):
    N = 2 × M
    (Half incubating, half producing)

    Per-Room Harvest Rates

    18 × 30 ft66.7 kg/day
    18 × 40 ft106.7 kg/day
    18 × 60 ft166.7 kg/day
    18 × 70 ft200 kg/day

    Example: 500 kg/day Target

    Using 18×70 ft rooms (200 kg/day harvest rate):
    M = ceil(500 ÷ 200) = 3 production rooms
    N = 2 × 3 = 6 total rooms
    At any time, 3 rooms are in incubation (Day 0–30) and 3 rooms are producing (Day 30–60). This ensures continuous daily harvest.
    Calculator

    MushroomWale Production Calculator

    Plan your project with accurate calculations

    How many rooms do I need?

    Results

    Rooms in Production3
    Total Rooms Required6
    Actual Daily Output600.0 kg/day
    Annual Output219,000 kg

    Climate, Production & Electrical Specifications

    Climate & Airflow System

    Included in all room models

    • Dampers & Gravity Louvers
    • Insulated Ducts
    • CO₂ Controller
    • Temperature & RH Control
    • PLC Control Panel
    • Misting/Water Sprayer Line
    • Water Tank Connection

    Production Parameters

    60-day cycle | CO₂: 800-1200 ppm | RH: 88-95%

    Spawn Run
    Mycelium colonization
    25–28°C
    Casing
    Casing application
    23–24°C
    Pinning
    Pin initiation
    16°C
    Cropping
    Harvest period
    14–16°C

    Electrical Specifications

    Panel compatible with high ambient load (45–50°C)

    Sensor Wiring
    1 mm copper
    Light Wiring
    1.5 mm copper
    Machine Wiring
    4 mm 4-core
    Comparison

    Quick Comparison

    Side-by-side specifications of all standard room models

    Specification18 × 30 ft18 × 40 ft18 × 60 ft18 × 70 ftRecommended
    Bag Capacity1,000+1,600+2,500+3,000+
    Yield per Cycle2,000 kg3,200 kg5,000 kg6,000 kg
    Cycle Average (60 days)33.3 kg/day53.3 kg/day83.3 kg/day100 kg/day
    Harvest Average (30 days)66.7 kg/day106.7 kg/day166.7 kg/day200 kg/day
    Rack Length22 ft32 ft52 ft62 ft
    Daikin AC6 TR8 TR10 TR12 TR
    BTU Rating72,000 BTU96,000 BTU120,000 BTU144,000 BTU
    LED Battens14 units20 units32 units40 units

    Ready to Build Your Mushroom Project?

    Use our calculators to plan your production capacity or get a detailed quotation for your grow room setup.

    Mushroom Grow Room FAQs