MushroomWale - Turnkey Mushroom Project Solutions
    You're offline — cached content is available
    Back to All Grow Rooms

    18 × 40 ft Grow Room

    Standard button mushroom cultivation room with Daikin refrigeration, designed for Indian conditions up to 50°C ambient temperature.

    1,600+
    Bags
    3,200 kg
    Per Cycle
    106.7 kg
    Harvest/Day
    8 TR
    Daikin

    18×40 ft Rack Layout

    18' × 40' Room18'40'Row A (5')Aisle (3')Row B (5')32' RacksEntry
    Bags:1,600
    Rows:2 Rows
    Tiers:7 Tiers

    Production Timeline

    60-day cycle: Incubation (Day 0–30) + Production (Day 30–60)

    Incubation
    Day 0–30
    No harvest
    Production
    Day 30–60
    106.7 kg/day
    Cycle Average (60 days)
    53.3 kg/day
    Harvest Average (30 days)
    106.7 kg/day
    For continuous daily harvest, use pairs of rooms: while one room is in incubation (Day 0–30), another produces (Day 30–60). Total rooms needed = 2 × Production rooms.

    Complete Specifications

    Room Dimensions

    Room Size18 × 40 ft
    Front Height16 ft
    Back Height14 ft
    PUF Walls80 mm
    PUF Common Wall60 mm
    PUF Roof80/110 mm corrugated

    Rack Layout

    Number of Rows2 rows
    Row Width5 ft each
    Row Length32 ft
    Stack Levels7 levels
    Rack MaterialPET wire mesh on MS frames
    Center WalkwayMin 3 ft

    Production Capacity

    Bag Capacity1,600+ bags (10 kg)
    Yield per Bag2 kg
    Cycle Length60 days (30+30)
    Yield per Cycle3,200 kg
    Cycle Average (60 days)53.3 kg/day
    Harvest Average (30 days)106.7 kg/day

    Refrigeration System

    BrandDaikin
    Capacity8 TR
    BTU Rating96,000 BTU
    Max Ambient50°C
    LED Battens20 units

    Production Parameters

    Spawn Run

    Temperature25–28°C
    RH90–95%
    CO₂10,000–15,000 ppm

    Casing

    Temperature23–24°C
    RH92–95%
    CO₂5,000–8,000 ppm

    Pinning

    Temperature16°C
    RH90–92%
    CO₂800–1,200 ppm

    Cropping

    Temperature14–16°C
    RH88–92%
    CO₂800–1,200 ppm

    Scope of Supply

    Structural

    • PUF insulated walls (80mm density 40±2)
    • PUF common wall (60mm)
    • PUF roof panels (80/110mm corrugated)
    • MS frame structure with powder coating
    • PET wire mesh racks (7 levels)
    • Aluminum/SS door with gasket seal
    • Drain point with trap

    Mechanical

    • Daikin refrigeration unit
    • EC fans for air circulation
    • Insulated duct system
    • Dampers and gravity louvers
    • Misting/fogging line
    • Water tank inlet connection
    • Condensate drain system

    Electrical

    • Main distribution panel
    • PLC control panel
    • LED batten lights
    • Temperature sensors
    • Humidity sensors
    • CO₂ controller
    • Wiring (1mm/1.5mm/4mm as required)

    Civil Requirements (By Client)

    • Level RCC floor with anti-skid finish
    • Floor slope towards drain (1:100)
    • Waterproofing on floor
    • 3-phase power connection
    • Water supply point
    • Drainage connection

    Optional Add-ons

    HEPA Filter Unit

    99.97% air filtration for spawn run

    Extra Sensors

    Additional temp/RH monitoring points

    Automation Upgrade

    Full IoT with mobile app control

    Backup Generator

    Power backup system integration

    CCTV Integration

    Remote monitoring cameras

    Get a Custom Quote for 18 × 40 ft Grow Room

    Includes complete engineering, Daikin refrigeration, climate controls, and turnkey installation.